Lubrication & Maintenance/500 Hour/12 Month

OURGP12,000004A

–19–28JUL04–2/3

RG8098

–UN–18NOV97

Cast Stops

A—Cast Stops
B—Cast Stop

Checking Belt Wear

The belt tensioner is designed to operate within the limit
of arm movement provided by the cast stops (A and B)
when correct belt length and geometry is used.

Visually inspect cast stops (A and B) on belt tensioner
assembly.

If the tensioner stop on swing arm (A) is hitting the fixed
stop (B), check mounting brackets (alternator, belt
tensioner, idler pulley, etc.) and the belt length. Replace
belt as needed (see REPLACING FAN AND
ALTERNATOR BELTS in Service As Required Section).

Continued on next page