Installation 

MI 

27 

• Ambient  background  temperature  compensation  from  a  second 

temperature  sensor  (infrared  or  contact  temperature  sensor) 
ensures  extremely  accurate  results.  For  example,  the  output  of 
the  second  unit,  set  for  mV  output,  could  be  connected  to  the 
FTC2  analog  input  (0  to  5  VDC  corresponding  to  low  end  and 
high  end  of  temperature  range)  is  utilized  for  real  time 
compensation,  whereby  both  sensors  must  be  set  on  the  same 
temperature range. 

Figure 16: Principle of Ambient Background Temperature 

Compensation 

Sensor 2

targeted

to ambient

Sensor 1

targeted

to object

Thermal radiation
of ambient

Thermal radiation
of target

0 – 5 VDC

analog output
at FTC2 input

Furnace wall

Target object