ST60 Tridata Instrument Owner’s Manual

Fitting the low-profile bezel
In order to flush-mount your ST60 instrument, you must first replace the
standard bezel with the low-profile bezel as follows:

1. Hold the instrument in both hands with the display towards you.

2. Using both thumbs, gently press an upper corner of the instrument

from the bezel, then remove the bezel from the instrument. Retain the
rubber keypad which is released when the bezel is removed.

3. Referring to the Fitting the low-profile bezel illustration, place the

instrument face upwards on a flat surface and place the rubber keypad
(7) in position around the display window (i.e. so that each key out-
line is located over its associated key on the instrument).

4. Snap the low-profile bezel (8) in position over the instrument, so that

the rubber keys are correctly located in the holes on the bezel.

CAUTION:
It is essential that only screws of the correct size are used to secure the
instrument to the bezel. Failure to observe this caution could result
in damage to both the instrument and the bezel.

5. Using the four, self-tapping screws (9) provided, secure the instru-

ment and bezel together. Fit the screws from the rear of the instrument
and tighten them sufficiently to secure the instrument and bezel
together. DO NOT OVERTIGHTEN.

D4537-2

81040_1.book Page 20 Thursday, November 7, 2002 10:21 AM