Chapter 3: Installation

25

Power supply connections

SeaTalk systems

CAUTION:
When instruments are connected to SeaTalk, ensure that the power
supply for the SeaTalk 12 V line is protected by a 5 A fuse.

Systems with a large number of instruments on the SeaTalk bus may
require connections to the power supply from each end of the system
(‘ring-main’ style), to maintain sufficient voltage throughout the system.

This requirement depends on the total length of the cable run and the total
number of instruments in the system, as follows:

Cable run

No. of instruments

Power connections

Up to 10 m

13 maximum
26 maximum

1
2

Up to 20 m

7 maximum
13 maximum

1
2

SPE

ED

DE

PT

H

White

Brown

Black

Screen

Blue

Connections to ST60 Tridata instrument

Cable from Depth transducer

Cable from Speed transducer

Screen
Green

SeaTalk cable

SeaTalk cable

D4423-1

Red

81040_1.book Page 25 Thursday, November 7, 2002 10:21 AM