Speed – Raymarine ST60 Tridata User Manual

Page 43

Advertising
background image

Calibration

31

Speed

To calibrate the speed functions:

1. With the User calibration entry screen displayed, press the speed key.

2. Referring to the User calibration - speed illustration, carry out the

calibration procedure. Use the speed key to cycle from screen to
screen and the trip and reset keys to set the required values at each
screen (except Adjust to SOG display).

Set speed units

Select either KTS (knots), MPH (miles per hour) or KMH (kilometres per
hour), as required.

Set speed resolution

Select resolution of either 0.01 or 0.1 as required.

Set log units

Select either NM (nautical miles), SM (statute miles) or KM (kilometres),
as required.

Setting the correct speed

Set the displayed (current) speed using one of the following methods:

Use the Adjust to Speed Over Ground (SOG) screen to automatically
set the current speed to SOG (if available from SeaTalk). You must be
running in slack tide conditions to successfully use this method.

Manually apply a calibration factor by means of the Cal factor adjust
screen, to set the displayed speed value to your best estimate of the
vessel’s speed.

81040_1.book Page 31 Thursday, November 7, 2002 10:21 AM

Advertising