Raymarine ST60 Tridata User Manual

Page 48

Advertising
background image

36

ST60 Tridata Instrument Owner’s Manual

Note: It is recommended that the speed calibration procedure is carried
out in conditions of minimum tidal drift.

To carry out a speed calibration, start the Intermediate calibration
procedure and use the

speed

key to proceed to the Calibration run length

screen (see sheet 1 of the Speed calibration flow chart). Proceed with the
speed calibration as follows:

1. With the Calibration Run Length screen displayed, press the

trip

and

reset

keys together to enter adjust mode. In this mode, the displayed

run length flashes on and off.

2. Set the length of the intended calibration run, using either the

trip

key

to decrement or the

reset

key to increment the run length value. You

can set any value between 0.25 and 2.50.

3. Press trip and reset keys together to commence the speed calibration.

The Cal status screen is displayed. The text at the bottom of the screen
alternates between Strt 1 and the calibration factor (CF) currently
applied.

4. Start first outward leg of the calibration run and as you pass the start

point, press the

speed

key, so that the text out shows at the bottom of

the screen. As the calibration run proceeds, the displayed value will
increment.

5. At the end of the measured distance on the outward leg, press the

speed

key again so that:

The text rEtrn is flashing at the bottom of the screen.

The displayed distance freezes. Note that this value will not be the
same as the measured distance due to errors introduced by tidal
flow.

6. Turn the vessel round, start the return leg and as you do so, press the

speed

key so the rEtrn legend stops flashing and the displayed value

increments.

7. At the end of the return leg, press the

speed

key to end the calibration

run. At this point:

The text Strt 2 alternating with the new calibration factor is dis-
played at the bottom of the screen.

The displayed distance freezes. This value should be very close to
the actual (measured) distance of the calibration run.

8. Press the

depth

and

speed

keys together, to store the new calibration

factor.

81040_1.book Page 36 Thursday, November 7, 2002 10:21 AM