Leaving user calibration – Raymarine ST60 Tridata User Manual

Page 45

Advertising
background image

Calibration

33

Adjust to SOG

The Adjust to SOG screen is displayed only if SOG data is available from
SeaTalk. The current SOG is displayed in the bottom section of the
display (SG12.8 in the illustration), and the current speed registered by the
instrument, as large figures in the middle section of the display (12.3 in
the illustration).

It is recommended that, if you are running in slack tide conditions, you
press the

reset

key for 3 seconds, to accept the SOG as the current speed.

If you do not wish to accept SOG as the current speed, press the

trip

and

reset

keys together to select the Cal factor adjust display.

Cal factor adjust
The Cal factor adjust screen enables you to manually adjust the
calibration factor. It shows the current calibration factor in the bottom
section of the display (CF 1.00 in the illustration), and the current speed as
large figures (12.3 in the illustration).

Use the

trip

or

reset

key to adjust the calibration factor so that the current

speed is the speed through the water.

If SOG data is available from SeaTalk, you can turn to the Adjust to SOG
screen by pressing the

trip

and

reset

keys.

Note: If neither of the above methods gives satisfactory results, carry out
the Speed calibration procedure (part of Intermediate calibration).

Set temperature units

Select either °C or °F, as required.

Temperature calibration

Set the display to show the current water temperature.

Timer alarm buzzer

Switches the count-up and race-start timer audible alarm on the ST60
Tridata instrument being calibrated, on and off.

Leaving User calibration

Hold down the

depth

and

speed

keys for 2 seconds, to save your settings,

exit User calibration and resume normal operation.