26

ST60 Tridata Instrument Owner’s Manual

Stand alone instruments
Stand-alone instruments are not connected to SeaTalk and therefore need
to be connected to an alternative 12 V power source. Power cables are
available in 2 m and 9 m lengths.

To fit a power cable:

1. Ensure the intended power source is switched off. If you are using a

12 V battery, ensure the power cable is not connected to the battery.

2. Run the power cable from the instrument to a suitable 12 V dc power

source.

3. If the cable has not already been trimmed at the power supply end:

Cut the cable to length and trim back an appropriate amount of the
outer sheath.

Cut back and insulate the yellow wire.

4. Connect the screen to the power supply 0 V terminal.

5. Connect the red wire via a 3 A over-current circuit breaker to the

power supply +12 V terminal.

D4311-1

5 A fused,

12 V dc supply

(typically provided

by autopilot)

Red

Screen

Red

Screen

1

2

3

4

Instruments

5 to 16

17

18

19

20

SeaTalk power connections

81040_1.book Page 26 Thursday, November 7, 2002 10:21 AM