Table 4-9, Bt8960 – Rockwell SoniCrafter BT8960 User Manual

Page 87

Advertising
background image

77

4.0 Electrical & Mechanical Specifications

4.5 Channel Unit Interface Timing

Bt8960

Single-Chip 2B1Q Transceiver

N8960DSB

Table 4-9. Channel Unit Interface Timing Requirements, Parallel Slave Mode

Symbol

Parameter

Minimum

Maximum

Units

18

TBCLK, RBCLK Period

(1)

T

QCLK

T

QCLK

19

TBCLK

,

RBCLK Pulse-Width High

T

QCLK

÷

4

20

TBCLK

,

RBCLK Pulse-Width Low

T

QCLK

÷

4

21

TQ[1,0] Setup prior to TBCLK Active Edge

(2)

25

ns

22

TQ[1,0] Hold after TBCLK High/Low

(2)

25

ns

Notes: (1). TBCLK and RBCLK must be frequency locked to QCLK though they may have independent phase relationships to QCLK

and to one another.

(2). TBCLK polarity (edge sensitivity) is programmable through the CU Interface Modes Register [cu_interface_modes

0x06].

Table 4-10. Channel Unit Interface Switching Characteristics, Parallel Slave Mode

Symbol

Parameter

Minimum

Maximum

Units

23

RQ[1,0] Hold after RBCLK Active Edge

(1)

0

ns

24

RQ[1,0] Delay after RBCLK High/Low

(1)

100

ns

Notes: (1). RBCLK polarity (edge sensitivity) is programmable through the CU Interface Modes Register [cu_interface_modes;

0x06].

Figure 4-4. Channel Unit Interface Timing, Parallel Slave Mode

Note:

TBCLK and RBCLK polarities are programmable through the CU Interface Modes register. The figure depicts both clocks
programmed to falling-edge active.

RQ[1:0]

TBCLK

TQ[1:0]

RBCLK

18

19

20

21

22

23

24

18

19

20

Advertising