1 test and diagnostic interface timing, 1 test and diagnostic interface timing, Bt8960 – Rockwell SoniCrafter BT8960 User Manual

Page 94

Advertising
background image

84

4.0 Electrical & Mechanical Specifications

4.6 Microcomputer Interface Timing

Bt8960

Single-Chip 2B1Q Transceiver

N8960DSB

4.6.1 Test and Diagnostic Interface Timing

Table 4-15. Test and Diagnostic Interface Timing Requirements

Symbol

Parameter

Minimum

Maximum

Units

56

TCK Pulse-Width High

80

ns

57

TCK Pulse-Width Low

80

ns

58

TMS, TDI Setup prior to TCK Rising Edge

(1)

20

ns

59

TMS, TDI Hold after TCK High

(1)

20

ns

Note:

(1). Also applies to functional inputs for SAMPLE/PRELOAD and EXTEST instructions.

Table 4-16. Test and Diagnostic Interface Switching Characteristics

Symbol

Parameter

Minimum

Maximum

Units

60

TDO Hold after TCK Falling Edge

(1)

0

ns

61

TDO Delay after TCK Low

(1)

50

ns

62

TDO Enable (Low Z) after TCK Falling Edge

(1)

2

ns

63

TDO Disable (High Z) after TCK Low

(1)

25

ns

64

SMON Hold after HCLK Rising Edge

(2)

0

ns

65

SMON Delay after HCLK High

(2)

50

ns

Notes: (1). Also applies to functional outputs for the EXTEST instruction.

(2). HCLK must be programmed to operate at 16 times the symbol rate (16 x F

QCLK

).

Advertising