16.5 Pressure Switch

Pull off 3 way connector. Spring open plastic clips of
mounting cradle. Replace with correct type of
pressure switch for model. The pressure switches
are colour coded for each pressure setting.

Carbon Monoxide Hazard

Use correct pressure switch specified for each model.

Use of incorrect pressure switch could cause unsafe

condition.

Failure to follow these instructions can result in

death or serious injury.

WARNING

Carry out a commission after working on or
changing a pressure switch.

See Page 24, Section

11.

Pressure

Switch

CTU-22

CTU-30

CTU-35

CTU-40

CTU-50

CTU-60

CTU-75

CTU-90

CTU-100

CTU-115

RG P/N

90439801

90439810 90439804 90439803 90439810 90439802 90439811 90439807 90439811 90439807

Colour

Code

pink

grey

white

grey

grey

yellow

grey

brown

grey

brown

Set Point

mbar

0.57

0.92

1.17

1.02

0.87

0.80

1.79

1.69

1.79

1.69

in wc

0.23

0.37

0.47

0.41

0.35

0.32

0.72

0.68

0.72

0.68