Assembly – Roberts Gorden COMBAT CTU 22 TO 115 User Manual

Page 46

Advertising
background image

COMBAT

®

CTU U

NIT

H

EATERS

I

NSTALLATION

O

PERATION

AND

S

ERVICE

M

ANUAL

40

16.6 Ignition Control

IT IS IMPORTANT THAT ONLY THE CORRECT
IGNITION CONTROL SPECIFIED FOR EACH
MODEL TYPE IS USED WHEN REPLACING
THESE ITEMS.

16.6.1 S4565C Models 22 to 60

This control plugs onto the gas valve. Pull out 12 pin
electrical connection. Pull out ignition cable and
flame probe cable noting their positions

Release screw securing control to gas valve

Refit in reverse. Ensure correct location of ignition
and flame probe cables. Ensure that the earth
connection is made directly to the earth point on the
gas valve.

16.6.2 S4563C Models 75 to 115

This control is mounted at the electrical mounting
plate. Pull out the 3 cable connectors.

Pull out ignition cable, ignition earth and flame probe
cable noting their positions. Remove the screws.
Refit in reverse. Ensure correct location of ignition
and flame probe cables.

16.7 CTUA Axial Fan/Guard/Motor Assembly

The axial fan unit for the CTUA heater is
supplied completely assembled and balanced.

16.7.1 Fan Removal

Remove the four screws

and rubber washers.

Description

Part Number

Axial Fan 16 in.

90710418

Axial Fan 500 mm.

90710419

and Replacement

16.7.2 To Replace the Fan Assembly

To replace the fan assembly, reverse the procedure
shown above. Fit rubber washers to the guard
mountings to reduce vibration.

• Check that the fan blades are free to rotate

before turning on the power to the fan.

• Strictly comply with the colour code of the fan

wires to ensure correct operation.

See Page 16,

Section 10.3 through Page 17, Section 10.4 wir-
ing diagrams

• Use only genuine ROBERTS GORDON

®

replacement parts.

16.8 CTUB & CTUC Centrifugal Fan/Guard/Motor
Assembly

The direct drive fan/s for the CTUB & CTUC range is
supplied as a complete assembly. Take careful note
of the electrical connections of the fan before
disconnecting from the terminals.

For the CTUC versions fitted with an inlet spigot
assembly, the fans may be accessed through the
removable covers on the sides, top and bottom of
the spigot, as required.

16.8.1 Fan Removal and Replacement

20 mm x 5 mm Adhesive Seal

is applied to the flange.

Description

Part Number

Torin Fan DDC 270-270

A047

Torin Fan DDC 241-241

A049

Remove the fan by removing the fixing screws while
supporting the weight of the fan (approx. 19 kg).

16.8.2 To Replace the Fan(s)

To reassemble, reverse the procedure shown above.

• Fit new rubber seal between the fan flange and

the heater rear panel.

• Fit to the rear panel in the correct orientation as

shown

on Page 41, Figure 14.

• Strictly comply with the colour code of the fan

wires to ensure correct operation.

See Page 18,

Section 10.5 through Page 20, Section 10.7

wiring diagrams.

Advertising