Section 12: user instructions, Figure 13: heater operating sequence, Ctions – Roberts Gorden Compact Tubular Unit Heaters CTCU 27 User Manual

Page 31: Section 12, Danger, Warning

Advertising
background image

SECTION 12: U

SER

I

NSTRUCTIONS

25 of 42

SECTION 12: USER INSTRUCTIONS

12.1 User Instructions

The CTCU heaters are fully automatic and operate
from the external controls fitted on site.

The only user controls at the heater are the:

Burner Lockout Reset Button:
See Page 26, Section 12.3.2
Limit Thermostat Reset Button:
See Page 25, Section 12.3.1

12.2 Heater Operation

When the heater has been switched on by the
remote controls installed on site, the main burner will
automatically turn on.

The burner control box will control the safe ignition
of the flame.

All heaters require a constant gas and electricity
supply which must not be interrupted during the
normal operation of this heater.

Figure 13: Heater Operating Sequence

12.3 Common User Controls

12.3.1 Fan Thermostat

The fan thermostat is located inside the access door
at the top of the heater.

See Page 38, Section 16.3.

This control ensures the heater does not blow cold
air in the normal heating cycle.

DANGER

Electrical Shock Hazard

Disconnect electric before service.

Heater must be properly grounded.

Failure to follow these instructions can result
in death or electrical shock.

Fire Hazard

Keep all flammable
objects, liquids and
vapors the minimum
required clearances to
combustibles away
from heater.

Some objects will catch
fire or explode when
placed close to heater.

Cut/Pinch Hazard

Wear protective gear
during installation,
operation and service.

Edges are sharp.

WARNING

Failure to follow these instructions can result in death, injury or property damage.

Burn Hazard

Allow heater to cool
before service.

Tubing may still be hot
after operation.

Explosion Hazard

Turn off gas supply to
heater before service.

Advertising