16.4 Flue Fan Vertical Installation (Models 7 - 15)

IT IS IMPORTANT THAT ONLY THE CORRECT FLUE FAN SPECIFIED FOR EACH MODEL TYPE IS
USED WHEN REPLACING THESE ITEMS.

Carry out a commission after working on or changing a flue fan.

See Page 25, Section 12.

MODEL

CTCU-7

CTCU-11

CTCU-15

Flue Fan

Fasco

7021-11767

Fasco

7021-11767

Fasco

7021-11767

RG P/N

90710470

90710470

90710470

Air Plate mm Ø

35

44

57

in Ø

1.38

1.75

2.25

RG P/N

11111210

11112210

11113210

1. To remove the fan, remove 3

screws securing the fan/
mounting plate to the vent box.

2. To remove the fan from the

mounting plate, remove the 4
screws.

3. Refit in reverse order.
4. To change the flue and air

intake orientation from back to
top, remove the fan/mounting
plate as explained in Steps 1
and 2.

5. Remove intake and exhaust

cover(s) from top of the heater.

6. Rotate the fan, mounting plate

and gasket clockwise until the
flue adapter lines up with the
top hole. Secure with 3 screws.

7. Remove the flexible duct from

the air intake adapter on the
back.

8. Remove the air intake adapter

from the back of the heater.
Install in the appropriate hole
on top.

9. Reconnect the flexible duct.
10.Install intake and exhaust

cover(s) over the holes on the
back of the heater.

11. Ensure sealed joints. Ensure

mounting plate orifice is clear
and not obstructed.