3 ignition electrode and flame probe – Roberts Gorden Compact Tubular Unit Heaters CTCU 27 User Manual

Page 44

Advertising
background image

COMBAT

®

CTCU U

NIT

H

EATERS

I

NSTALLATION

O

PERATION

AND

S

ERVICE

M

ANUAL

38 of 42

16.3 Ignition Electrode and Flame Probe

Burners

.120

(3 mm)

spark

gap

Ignition

Electrode

Burner Compartment

Front Views

Limit

Thermostat

Ignition

Electrode

Flame

Probe

Fan

Thermostat

Flame

Probe

Burners

Description

Part Number

Spark Electrode

90427411

Automatic Ignition Flame Probe

90439300

Burners

92000002

Fan Thermostat

90412102

Limit Thermostat

90412100

To replace the ignition electrode or flame probe, remove the electrical lead and screw.
Pull out from mounting. Refit in reverse ensuring that the gap to burner is as shown in the
front view of the burner compartment.