Roberts Gorden Compact Tubular Unit Heaters CTCU 27 User Manual

Page 48

Advertising
background image

COMBAT

®

CTCU U

NIT

H

EATERS

I

NSTALLATION

O

PERATION

AND

S

ERVICE

M

ANUAL

42 of 42

16.7 Ignition Control

This control is mounted at the bracket plate. Pull out
the three cable connectors. Pull out ignition cable,
ignition earth and flame probe cable noting their
positions. Located behind the bracket ignition
control are the white mounting pins. Depress locking
tab while gently pulling bracket away from mounting
pins to disengage the bracket. Remove the screws.
Refit in reverse. Ensure correct location of ignition
and flame probe cables.

16.8 CTCUA Axial Fan/Guard/Motor Assembly

The axial fan unit for the CTCUA heater is
supplied completely assembled and balanced.

16.8.1 Fan Removal and Replacement

16.8.2 To Replace the Fan Assembly

To replace the fan assembly, reverse the procedure
shown above. Fit rubber washers to the guard
mountings to reduce vibration.

• Check that the fan blades are free to rotate

before turning on the power to the fan.

• Strictly comply with the colour code of the fan

wires to ensure correct operation.

See Page 20,

Section 10.3 wiring diagram.

• Use only genuine replacement parts sold and

supplied by Roberts-Gordon.

16.9 Fan and Limit Thermostats

16.9.1 Removal and Replacement

1. Pull off the electrical connections to the

thermostat

2. Unscrew the two screws securing the

thermostat

3. Fit a new thermostat with two screws ensuring

that the correct temperature setting and type
are selected.
See Page 9, Section 5.3.

4. Reconnect the electrical connections and test

operation.

Remove the screws

and washers.

Description

Part Number

Axial Fan CTCU-7

11111910

Axial Fan CTCU-11

11111911

Axial Fan CTCU-15

11111920

Axial Fan CTCU-22

11111921

Axial Fan CTCU-27/32

11111922

Advertising