4.2 Setting a New IP Address over the Network

Besides using the iConnect software, you may use the Coordinator’s default IP address to
access it and assign a new IP address to it.

The Coordinator is shipped with a default IP address of 192.168.1.200 and Subnet Mask of
255.255.255.0.

You can configure your PC’s Network connection (See Section 3.5.2 for more details) with
an IP address that is in the same range as the Coordinator’s IP address (192.168.1.x) and
connect to the Coordinator using a crossover network cable between your PC and the
Coordinator.

With this completed, you can go to the DOS-Prompt and ping 192.168.1.200.
If you receive responses back (Figure 4.1), you can go to the Web browser and type in

http://192.168.1.200 and it will take you to the zSeries Home Page.

Select

, button, you’ll be asked for the password. You should be on the

Access Control page were you can simply type in the desired Static IP address, and click Save.

For more details about the "Access Control" page refer to Section 4.3.9.

Figure 4.4 Access Control

For the IP address to take effect, the Coordinator needs to be turned OFF and ON using
the "Network Reset" button. Pressing the physical button marked "RESET" on the
Coordinator does the same thing.

You can now connect the Coordinator to an Ethernet hub using a straight through cable,
power it up, and follow the ping routine mentioned in the previous section.

Access Control

ACCESS CONTROL

ACCESS CONTROL

http://192.168.1.200

Address

Main Menu

Login Password 12345678

Admin Password 00000000

IP Address

192.168.1.200

Gateway Address

0.0.0.0

Subnet Mask

255.255.255.0

MAC Address 00:03:34:00:85:C4

Host Name

z85C4

Save

Reset

Network Reset