Omega Vehicle Security Wireless Sensor System zSeries User Manual

Page 82

Advertising
background image

76

Appendix F

ASCII /TELNET COMMANDS TABLE (continued)

* An example of the status of an End Device

Command:

EQNG00A

Response:

7

EngrLAB 01000010 2.0

7 is the Device ID (DID) of the End Device.

EngrLAB is the name for the End Device.

"01000010" is the bitmap representation of the internal state. The meaning for each bit is
described below (bit 7 starts from the left).
2.0 is version of the firmware in the End Device.

Based on the above information, End Device # 7 has not been communicating with the
Coordinator and its power is supplied by an adapter.

Reading/parameter for ERDR command

End Device Types

Options Reading/parameter

(lower case)

a

Sequence number

b

Device type

c

First temp / error message

d

First RH / barometric pressure
/ error message

e

Second temp / error message

f

Second RH / barometric
pressure / error message

i

Update rate

j

Battery voltage

k

Signal strength

l

Success rate

q

Name

r

Status

s

Firmware version

Bit 7

shows if the sensor is plugged

into the End Device. ‘1’ means there is
no sensing device detected.

Bit 6

shows if the communication to

the End Device is lost. ‘1’ means there
has not been any data received from
that particular End Device for 1 minute
or 4 times the update rate, whichever is
a longer time interval.

Bit 5

shows if there is more than one

End Device having the same dip switch
configuration. ‘1’ means more than 1
End Device has the same Network ID
and Device ID.

Bit 4

shows if there is any pending "identify

mode request" command for the End Device.
‘1’ means a "start" command is issued.

Bit 3

not used

Bit 2

shows if there is any pending "reset"

command for the End Device. ‘1’ means a
"reset" command is issued.

Bit 1

shows the source of power supply to

the End Device. ‘1’ means it’s powered by an
adapter and ‘0’ means it’s powered by
batteries.

Bit 0

shows the operation mode of the End

Device. ‘1’ means it is in identification mode
and ‘0’ means it is in normal operation mode.

ZED_T

1

ZED_BT_THP

11

ZED_T_BTP

2

ZED_BT_TP

12

ZED_T_THP

3

ZED_BTH

13

ZED_T_TP

4

ZED_BTP

14

ZED_TH

5

ZED_THP

15

ZED_TH_BTP

6

ZED_TP

16

ZED_TH_THP

7

ZED_TH_TP

8

ZED_BT

9

ZED_BT_BTP

10

ZED_TC

20

Advertising