INTERFACE SPECIFICATIONS (zCDR)

Ethernet:

Standards Compliance IEEE 802.3 10Base-T (RJ45)

Supported Protocols:

TCP/IP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet

LED Indicators:

Network Activity, Network Link, Diagnostics, Receive and Power

Management:

Device configuration and monitoring through embedded WEB server

Embedded WEB Server: Serves WEB pages (Java™ Applets) containing real-time data

and live updated charts within definable time intervals

WIRELESS COMMUNICATION

Standard:

IEEE 802.15.4, DSSS

Frequency:

2.4 GHz (2400 to 2483.5 MHz), 16 channels

Network Topology:

Star Topology

Radio Power Output:

100 mW (20 dBm); 10 mW (10 dBm)

Limitations on Equivalent Isotropic Radiated Power (EIRP) levels in the European
Community and other countries applies. An improper combination of power level can
result in an EIRP above the allowed amount per regulations. See Appendix H.

Data Rate:

Bit rate 250 Kp/s; Symbol rate 62.5 Symbol/s;
Chip rate 2000 kchip/s

Modulation:

Orthogonal Quaternary Phase Shift Keying (O-QPSK)

Receiver Sensitivity:

-100 dBm

Range:

zED

Up to 91 m (300 ft) without obstructions or interference

zED-P/-LCD/-H

Up to 1000 m (3280 ft) without obstructions or interference

-AA/-CCELL/-DC-H2

The above ranges assume a line-of-Sight (LOS) between the Meter/Receiver and
End Device without obstructions or interference at which the diagnostic signal
strength web interface registers approximately 25%.

Antenna Frequency:

2400 to 2500 Mhz

Impedance:

50 ohm

Connector:

Reverse Polarity SMA Plug

Emission Designation:

2M00M1D

Channel Spacing:

5 MHz

POWER (zCDR)

Power Input:

9 to 12 Vdc

Consumption:

2.5 W max.

Safety Qualified ac Power Adapter (included)

Nominal Output:

9 Vdc @ 0.5 A

Input:

100 to 240 Vac, 50/60 Hz

65