4.8.3 Device Setting and Configuration

Make sure that the Coordinator is configured (using web access, see Figure 4.17) to the
settings below.

TCP Connection = any value from 1 to 5

Port number = 2000 (other values may be acceptable as long as Mail Notifier is setup
with the same Port number).

Then on the Mail Notifier Alarm Editor:

1) Set the "IP address" (for example 192.168.1.200).

2) Specify "Socket Number" 2000.

3) Set the "Address/RS485 Unit" to the Device ID number for an End Device.

4) Set the "Reading Cmd" using general commands in the following Table below.

5) Define the Alarm Configuration (High/Low, High value, or Low value).

Specify Email Interval. This determines how many seconds each subsequential
alarm notification will be sent.

Determine Monitor interval. This establishes the interval or time resolution in
seconds for which readings will be obtained from the device.

Table 4.2 Mail Notifier Commands

Desired Value to Monitor

Reading Cmd string

Actual Command String
(see Note 2)

Reading A

zRdgA

ERDB003

Reading B

zRdgB

ERDB003

Reading C

zRdgC

ERDB003

Reading D

zRdgD

ERDB003

Battery voltage (mV)

zBatt

EQPE003

Signal Level

zSignal

EQPE003

Sleep Interval

zSleep

EQPE003

Status (see Note 4)

zAddress

EQNF003

1. The End Devices are configured in Mail Notifier with symbolic commands

rather than actual device commands.

2. zRdgA with RS485 Device Unit # as 3, for example, is sent as ERDB003.

3. "Reading A" will be the first value returned for a device in response to a

command such as ERDB003.

4. "Status" can be used to detect an address conflict. The value should be

tested to be at value 32 if there is an address conflict.