3.2.2.3. OXYGEN DISPLAYS

If set to EAN mode the NITROX display, with all

labeled oxygen information, is shown immediately after

activation. The nitrox display shows (Fig. 3.21.):

•

oxygen percentage, labeled with O

2

%, is

shown in the left side of the lower display

•

set oxygen partial pressure limit, labeled with

PO

2

, is shown in the right side of the lower

display

•

maximum allowed depth based on the set

oxygen percentage and partial pressure limit

•

current oxygen toxicity exposure shown with

an Oxygen Limit Fraction (OLF) bar graph

along the right side of the display.

In the Dive mode the current oxygen toxicity exposure

is always shown with an Oxygen Limit Fraction (OLF)

bar graph and the oxygen percentage labeled with O

2

%.

The current oxygen partial pressure labeled with PO

2

is also shown, if selected (Fig. 3.22.). During a dive,

the oxygen partial pressure, labeled with PO

2

, is always

shown instead of the preselected display, if the partial

pressure is greater than 1.4 bar or the set value (Fig.

3.23.).

Fig. 3.23. Oxygen partial

pressure and OLF displays.

There is an audible alarm and the

last segment of the bar graph

starts to blink as the OLF has

reached 80% limit. When OLF

has reached 100%, all segments

starts to blink. If the OTU value

is higher than the CNS value, the

lowest segment blinks.