65

3.4. AUDIBLE AND VISUAL ALARMS

The dive computer features audible and visual alarms to advise when important

limits are approached or to acknowledge preset alarms.
A short single beep occurs when:

•

when the dive computer automatically returns to the Time mode.

Three single beeps with a two second interval and the backlight activated for

5 seconds occur when:

•

the no-decompression dive turns into a decompression stop dive. An arrow

pointing upwards and the blinking ascent warning ASC TIME will appear

(Fig. 3.17.).

Continuous beeps and the backlight activated for 5 seconds occur when:

•

the maximum allowed ascent rate, 10 m/min [33 ft/min], is exceeded.

SLOW and STOP warnings will appear (Fig. 3.15.).

•

the Mandatory Safety Stop ceiling is exceeded. A downward pointing arrow

will appear (Fig. 3.14.).

•

the decompression ceiling depth is exceeded. An error warning Er and a

downward pointing arrow appear. You should immediately descend to, or

below, the ceiling. The instrument will otherwise enter a permanent Error

Mode within three minutes, indicated by a permanent Er (Fig. 3.20.).