Oregon PowerScan Handheld Laser Scanner User Manual

Page 113

Advertising
background image

Programming Guide

107

UPC/EAN

Add-ons

There are many ways to configure the scanner to handle add-ons. The
scanner uses four filters that can be specified to define how add-ons
will be handled. The following is true for each filter.

Each add-on type can be disabled, required or optional.

Any combination of the four UPC/EAN symbologies can be
affected.

The 2-digit, 5-digit and C128 add-ons can be individually
configured.

The leading digits of the base labels affected can be specified.

This programming guide supports the following add-on filters for
UPC/EAN:

Required

means that UPC/EAN labels MUST contain a

2-digit, 5-digit or C128 add-on segment in order for the scanner
to recognize or decode them.

Optional

directs the scanner to recognize UPC/EAN bar codes

with or without P2, P5 or C128 2-digit add-on segments.

Disable Add-ons

means the scanner will not recognize or

decode any add-on segment of UPC/EAN labels, but will read
and decode the standard UPC/EAN portion of the label.

NOTE

The settings below represent only a small por-
tion of the options available for this feature.
Contact your sales representative or service
provider if you need more assistance with
advanced add-on settings.

NOTE

Due to the structure of add-on codes, selecting
the optional setting makes it impossible to
ensure that the scanner will always read the
add-on portion of the label. PSC makes no
guarantee, either written or implied, that scan-
ners with optional add-on decoding enabled
will perform with the speed and accuracy
required for any given application.