61

Setting Single

Character

Label I.D.

The scanner will not transmit a label I.D. character if its hex value is set
to zero. If you have determined that you need a Label I.D. that contains
only a single character, follow this modified procedure:

1.

Scan the SET bar code on page on

page 58

.

2.

Scan your selection from the list starting on

page 58

for the

symbology identifier you plan to change.

For example, scan the EAN-8 bar code to select that symbology.

3.

Turn to the keypad (

Appendix C: Keypad

on page 147) and scan

the two-digit hex code that represents your desired character
(refer to the ASCII chart on the inside back cover of this man-
ual for this conversion).

4.

Scan the digit ‘0’

two

times to disable transmission of a

second character. Return to this page.

As an example, assume that you want to change the Label I.D. for
EAN-8 from the default setting “FF” to the single character “8”. In this
example, note that the chart shows that the ASCII character ‘8’ is equiv-
alent to 38 hex, therefore the digits 3, then 8 should be scanned fol-
lowed by two zeros (00) to indicate a single character I.D. (e.g., scan
3,8,0,0)

5.

Scan the END bar code on

page 60

.

Disabling

Label I.D. for a

Specific

Symbology

This procedure is the same as Setting Single Character Label I.D. above,
except you should scan

four

zeros before scanning the END bar code.

NOTE

Successful programming requires 4 digits for
the Label I.D.

NOTE

If you make a mistake or lose your place while
setting this option, scan the END bar code to
exit Programming Mode. The scanner will
sound a two-beep error tone to indicate that
programming was incomplete, and the setting
will remain as it was before entering Program-
ming Mode.