131

Using Socket Services with Socket Service Request Switches

Section 6-2

Program Memory Map

The send and receive data and bits (flags) used by the program are shown in
the following diagram.

DM Area

CIO Area

The following bits and flags are used to control CMND(490) execution. The
bits in CIO 0000 are used to signal execution, the bits in CIO 0001 are used to
signal errors, and the bits in CIO 0002 are used to control the program so that
the instruction is executed only once.

Send data, 100 bytes (100 = 0064 Hex)

Receive data, 100 bytes (100 = 0064 Hex)

7

6

5

4

3

2

1

0

CIO 0000

CIO 0001

15 to 8

CIO 0002

TCP
Send
Bit

TCP
Close
Bit

TCP
Open
Bit

TCP
Receive

Error
Flag

TCP
Send
Error
Flag

TCP
Close
Error
Flag

TCP
Open
Error
Flag

TCP
Receiving
Flag

TCP
Sending
Flag

TCP
Closing
Flag

TCP
Opening
Flag

TCP
Receive
Bit