Mounting, Connecting cables, Switching on the system – Tandberg Data N3 User Manual

Page 10: 2 mounting, 3 connecting cables, 4 switching on the system

Advertising
background image

TANDBERG Gatekeeper User Manual

4

Do not place heavy objects directly on top of the Gatekeeper.

Do not place hot objects directly on top, or directly beneath the Gatekeeper.

Use a grounded AC power outlet for the Gatekeeper.

2.2 Mounting

The Gatekeeper comes with brackets for mounting in standard 19" racks.

Before starting the rack mounting, please make sure the TANDBERG Gatekeeper is placed
securely on a hard, flat surface.

1. Disconnect the AC power cable.

2. Make sure that the mounting space is according to the `Installation site preparations' in
section 2.1.

3. Attach the brackets to the chassis on both sides of the unit.

4. Insert the unit into a 19" rack, and secure it with screws.

2.3 Connecting Cables

Power cable

Connect the system power cable to an electrical distribution socket.

LAN cable

Connect a LAN cable from the LAN 1 connector on the front of the unit to your local area
network.

Null-modem RS-232 cable

Connect the supplied null-modem RS-232 cable between the Gatekeeper

s Data 1 connector

and the COM-port on a PC.

2.4 Switching on the System

To start the TANDBERG Gatekeeper, make sure that the following has been done:

The power cable is connected.

The LAN cable is connected

Then switch the power switch button on the back of the unit to

1'.

On the front of the chassis you will see the Power LED being lit.