2. Expanded Functions


Expanded file register data Write [MW]


Request message format (Host

T3H):

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

( A ADR M W

Starting register

,

Bank

,

N

,

Data #1



Can be shortened

n-5

n-4

n-3

n-2

n-1

n

,

Data #N-1

, Data

#N &

Sum

)

CR



Can be shortened

Can be omitted


ADR:

Station address ... 01 to 32


Starting register:

For 8 k words per bank ..... F0000 to F8191

For 64 k words per bank ... f0000 to f65535 (bank 1)

f0000 to f57343 (bank 2)


Bank:

For 8 k words per bank ..... 1 to 15

For 64 k words per bank ... 1 to 2


N:

Number of registers to be written ... 1 to 46 (see Note)


Data:

Data in hexadecimal


Sum: Check

sum



Response message format (T3H

Host):

1 2 3 4 5 6 7 8 9 10

11

12

13

14

15

( A ADR S T

Status

&

Sum

)

CR



Status: T3H operation status



Upper case F

Lower case f