Figure 2-2 – Tandberg Data VXA-320 (VXA-3) User Manual

Page 24

Advertising
background image

10

P

RODUCT

M

ANUAL

433689-01

C

HAPTER

2 I

NSTALLATION

2.

Prepare the drive bay.

Remove the drive bay’s cover plate according to the system manufacturer’s

instructions.

3.

Set the SCSI ID jumpers, if necessary.

a.

The tape drive is shipped with a SCSI ID of 11. If another device on the

SCSI bus is already configured with this SCSI ID, you will need to change

the tape drive’s SCSI ID. Reposition the jumpers on the jumper block, as

shown in

Figure 2-2

, to select the desired ID. (If necessary, use flat-nose

pliers to remove the jumpers.) If you need an additional jumper, use a

2 mm jumper.

Alternatively, you can remove the jumpers and connect a cable (not

included) from a remote switch to the jumper block, then use the remote

switch to set the SCSI ID. The cable should use a connector equivalent to

Hirose Housing part number DF11-8DS-2C, 2.0MM 8CKT to connect to the

jumper block.

b.

Provide additional grounding, if desired.

Attaching the tape drive to the enclosure protects the tape drive from ESD.

However, if you want additional chassis grounding for the tape drive, use

the grounding hole or grounding tab on the back panel (see

Figure 2-1

):

Figure 2-2 SCSI ID settings

Address 0

Address 15

Address 1

Address 8

Address 9

Address 2

Address 3

Address 10

Address 11

Address 4

Address 5

Address 12

Address 13

Address 6

Address 7

Address 14

Factory
setting

!

Important

Each device on the SCSI bus must have a unique SCSI ID.

Advertising