External tape drive, Table 7-8, Table 7-9 – Tandberg Data VXA-320 (VXA-3) User Manual

Page 68

Advertising
background image

54

P

RODUCT

M

ANUAL

433689-01

C

HAPTER

7 S

PECIFICATIONS

DC Voltages

The internal tape drive operates from standard +5 and +12 VDC supply

voltages (all specified voltages are DC, no external AC power is used).

Note:

The VXA-320 tape drive does not provide overvoltage or overcurrent

protection, except for TERMPWR, which has a resettable fuse. Safety

agency certifications are based on the voltages being supplied by a Safety

Extra Low Voltage (SELV) source (per IEC 950).

Power Consumption

Table 7-9

shows the internal tape drive’s power consumption when operating

and when idle.

E

XTERNAL

T

APE

D

RIVE

The power specifications for the external tape drive include both the

requirements for the tape drive and the enclosure components.

Table 7-8 Power specifications (internal model)

Power

+5 Volts

+12 Volts

Required supply tolerance:

±5%

±10%

Ripple and noise: (50 Hz to 20 MHz)

a

250 mVpp max.

250 mVpp max.

Operating current (amps)

Read or write: 1.25 (average)

1.27 (peak)

0.51 (average)

0.57 (peak)

Search/high speed: 1.11 (average)

1.22 (peak)

0.59 (average)

2.00 (peak)

Load/unload: 1.00 (average)

1.20 (peak)

0.45 (average)

2.00 (peak)

Power up: 0.90 (average)

1.17 (peak)

0.08 (average)

0.44 (peak)

Idle: 0.83 (average)

0.06 (average)

a

The ripple voltage is included in the total voltage tolerance.

Table 7-9 Power consumption (internal model)

Power Consumption

Power (average)

Read or write:

12.4 watts

Search/high speed:

12.7 watts

Load/unload:

10.4 watts

Power up:

5.5 watts

Idle:

4.9 watts