External tape drive, Table 7-8, Table 7-9 – Tandberg Data VXA-320 (VXA-3) User Manual
Page 68
54
P
RODUCT
M
ANUAL
433689-01
C
HAPTER
7 S
PECIFICATIONS
DC Voltages
The internal tape drive operates from standard +5 and +12 VDC supply
voltages (all specified voltages are DC, no external AC power is used).
Note:
The VXA-320 tape drive does not provide overvoltage or overcurrent
protection, except for TERMPWR, which has a resettable fuse. Safety
agency certifications are based on the voltages being supplied by a Safety
Extra Low Voltage (SELV) source (per IEC 950).
Power Consumption
shows the internal tape drive’s power consumption when operating
and when idle.
E
XTERNAL
T
APE
D
RIVE
The power specifications for the external tape drive include both the
requirements for the tape drive and the enclosure components.
Table 7-8 Power specifications (internal model)
Power
+5 Volts
+12 Volts
Required supply tolerance:
±5%
±10%
Ripple and noise: (50 Hz to 20 MHz)
a
250 mVpp max.
250 mVpp max.
Operating current (amps)
Read or write: 1.25 (average)
1.27 (peak)
0.51 (average)
0.57 (peak)
Search/high speed: 1.11 (average)
1.22 (peak)
0.59 (average)
2.00 (peak)
Load/unload: 1.00 (average)
1.20 (peak)
0.45 (average)
2.00 (peak)
Power up: 0.90 (average)
1.17 (peak)
0.08 (average)
0.44 (peak)
Idle: 0.83 (average)
—
0.06 (average)
—
a
The ripple voltage is included in the total voltage tolerance.
Table 7-9 Power consumption (internal model)
Power Consumption
Power (average)
Read or write:
12.4 watts
Search/high speed:
12.7 watts
Load/unload:
10.4 watts
Power up:
5.5 watts
Idle:
4.9 watts