A service notification led code appears, Table 4-1, Led c – Tandberg Data VXA-320 (VXA-3) User Manual

Page 42

Advertising
background image

28

P

RODUCT

M

ANUAL

433689-01

C

HAPTER

4 T

ROUBLESHOOTING



Check that the SCSI controller and the most recent drivers available for

it are installed according to the manufacturer’s instructions.



Check that the SCSI controller is fully seated in its slot. You can also try

2.

Make sure the tape drive is installed properly on the bus, described in

Chapter 2

. In particular, check the following:



Is the tape drive set to a unique SCSI ID?



Is a terminator installed at the physical end of the SCSI bus? Try another

terminator.



Is there a broken cable or defective connector? Try another, known-good

cable.



Is the cable correctly oriented and firmly seated on the tape drive

connector?

3.

Check that the tape drive is powered-on and that its LEDs are not

indicating an error state. See

Table 3-1 on page 20

for a complete list of LED

states.

4.

Reboot your system.

5.

Try using VXATool to communicate with the tape drive. Before running

VXATool, stop all services for your backup application. If VXATool can

detect and communicate with the tape drive, but your backup application

cannot, contact the application provider for software support.

6.

Verify that the tape drive is supported by your operating system and

backup application. Refer to

“Integrating the Tape Drive” on page 18

for

details on how to confirm this information.

A S

ERVICE

N

OTIFICATION

LED C

ODE

A

PPEARS

If one of the Service Notification LED codes appears (see

Table 3-1 on page 20

),

refer to

Table 4-1

for error recovery procedures.

Table 4-1 Service Notification error recovery procedures

Service Notification

Suggested Recovery Procedure

Cleaning Required

Clean the tape drive. See

page 23

for cleaning instructions; LED 2 flashes amber

when the tape drive needs to be cleaned. Use only an Tandberg Data approved

VXAtape Cleaning Cartridge.

Cleaning Tape used

up

Discard the cartridge and use a new cleaning cartridge. Do not rewind and reuse

the material in a cleaning cartridge. Reuse may redistribute contaminants

previously removed from the tape path.