Tektronix 1740A/1750A User Manual

Page 48

Advertising
background image

Operator’s Checkout Procedure

2-18

1740A/1750A Series Waveform/Vector Monitor User Manual

Select

F+L+C

(

FLAT

plus

LUM

plus

CHROM

). The display is

similar to the

F+L

display, with the chrominance-filtered

signal added on the right.

Select

DIFF

. Select the generator 5-step staircase signal. The

differentiated-step filtered display appears similar to
Figure 2-9.

Select

R---Y

. This provides a demodulated chrominance-ver-

sus-time display. Use the right bezel control to adjust vector
phase. See Figure 2-10.

Select

SCH R---Y

(1750A only). This provides a demodulated

SC/H sync-locked oscillator display, useful for viewing SC/H
variations versus time. A sample NTSC display is shown in
Figure 2-11. NTSC signals can be viewed in either line or
field sweeps. For PAL applications, view the signal in
two-field sweep (see Figure 2-12). Use the right bezel control
to adjust vector phase.

Exit the

FILTER

menu. Enter the menu again and note that the

filter selections are unchanged. Select

FLAT

. Exit the menu.

10 S/DIV

FLAT

LUM

CHROM

DIFF

R--Y

SCH R--Y

F+L

F+L+C

Figure 2-9. Two-Line DIFF filter display of 5-step staircase signal.

Advertising