Displaying a signal, Time code, Multiple – Tektronix 1740A/1750A User Manual

Page 58: Inputs

Advertising
background image

Functional Overview

1740A/1750A Series Waveform/Vector Monitor User Manual

3-3

Time Code

Longitudinal time code is monitored in a frame-rate display
to allow observation of amplitude, synchronization, and
phase with respect to reference vertical sync. Synchroniza-
tion is confirmed by the stationary display and time code
phase is determined by horizontal position of the time code
sync word on the CRT.

Multiple

When

MULTIPLE

is pushed, any combination of front-panel

DISPLAY

modes can be selected at the same time, with the

exception of

TIME CODE

and

PICTURE

displays.

With

MULTIPLE

selected, the

SCH/AUDIO

switch sequences

through

SCH

,

AUDIO

,

and both. If waveform or vector is also

selected, the switch will also sequence to

OFF

. (At least one

mode must be on at all times.)

When exiting

MULTIPLE

, the instrument will return to the

previous (non-

MULTIPLE

) display settings. When entering

MULTIPLE

again, the previous

MULTIPLE

display settings will

be restored.

Displaying a Signal

Inputs

There are eight rear-panel loop-through inputs, which may
eliminate the need for an external routing switcher. The in-
puts can be displayed singly or in combination.

Without

PARADE

or

OVERLAY

selected, only one input selec-

tion can be made at a time. Each input channel button (in-
cluding

A123 / B123

) toggles between

A

and

B

,

and is

cancelled when another input button is pressed.

With

PARADE

or

OVERLAY

selected, the input channels can be

displayed in combination. Pushing an input channel button
sequences through the labeled channels, both, then off. Push-
ing another input button does not cancel the current selec-
tion, but adds to it. To return to “single input” operation,
push the

PARADE / OVERLAY

button until it is off (LED is no

longer lighted).

Advertising