5.

Install the replacement LCD Cover Assembly onto the base of the
notebook and secure using the hinge screws. Reconnect the two video
cables under the DAB Board and secure the DAB insulator to the top
of the board.

6. Install the original LCD bezel .When replacing the bezel, ensure that

the microphone is correctly positioned between the plastic tabs to
prevent binding when snapping the bezel in place. Also ensure that
the two locking pawls come throught the slits in the bezel (near the
top of the bezel). Replace the bezel screws and bezel screw rubber
inserts. Also replace the hinge covers. Test unit by carefully opening
and closing the notebook and looking for and correcting any signs of
binding.

Microphone Assembly

Right side Hinge Screws

Left Side Hinge Screws

Removing the Hinge Screws

Removing the Bezel

Step 1: Remove two

Snap On Plastic Hinge

Covers

Step 2: Remove two plugs and remove recessed screws..

Step 3: Gently pry off the

Display Bezel (held by clips)

Figure 5-19 LCD Cover Assembly, Removal/Replacement