Reserved

LCD Type

0000 = Mono
0001

=

Passive

Color

0010

=

Active

Color

0011

=

EL

0100 - 1111 = Reserved

DL = Reserved

CY = Set on error (see AH)

F.8

Function F9h - Subfunction 60h
Get Standby Level

This function returns the current standby level, and the maximum level
currently supported. This maximum level should be checked before setting
the level to ensure that the desired level is supported. Also, see related
function F961h.

Call with:

AH = F9h

AL = 60h

Returns:

AH = 00h

BH = Maximum Level Available

BL = Current Level

F.9

Function F9h - Subfunction 61h
Set Standby Level

This function sets the new standby level. Also, see related function F960h.

Call with:

AH = F9h

AL = 61h

BL = New Standby Level