Slide-in-modules, 2 installing the managment modules, Chassis – Transition Networks CPSMC0800-100 User Manual

Page 10: Panel fastener screw

Advertising
background image

10

CPSMC0800-100 PointSystem

Chassis

slide-in-modules

Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600

2.2.2

Installing the Managment Modules

CAUTION: Wear a grounding device and observe electrostatic discharge precau-
tions when installing the Management Module(s) in the 8-Slot chassis. Failure to
observe this caution could result in damage to, and subsequent failure of, the
Management Module.

Install one (1) Master Management Module (CPSMM-120 or CPSMM-200) in the
primary managed CPSMC0800-100 8-Slot chassis.

If several PointSystem™chassis are to be connected in a cascade fashion (see sec-
tion 4.3 Cascade Option):

Install one (1) Master Management Module (CPSMM-120 or CPSMM-200) into
the primary managed CPSMC0800-100 8-Slot chassis.

Install one (1) Master Management Module (CPSMM-200) or one (1) Expansion
Management Module (CPSMM-210) in any secondary managed CPSMC0800-
100 8-Slot chassis.

NOTE: Though the Management Module(s) can be installed in any PointSystem™
chassis slot, use of the left-most installation slot(s) for installing the Management
Module(s) is recommended in order to keep the cascading cables separate from the
network cables connected to the installed on Media Converter Slide-In-Modules.

To install a Management Module:

1a. CPSMM-200 Dual-Slot Master Management Module:

Remove two (2) Management Module protective plates from two (2) installation
slots at the far-left position by removing the one (1) screw that secures each pro-
tective plate to the PointSystem™ chassis.

1b. CPSMM-120 Single-Slot Master Management Module OR

CPSMM-210 Single-Slot Expansion Management Module:
Remove one (1) Management Module protective plate from one (1) installation
slot at the far-left position by removing the one (1) screw that secures the pro-
tective plate to the PointSystem™ chassis.

2. Align the Management Module with the PointSystem™ chassis installation slot

so that the panel fastener screw is to the left of the Management Module.

3. Carefully slide the Management Module into the installation slot, aligning the

Management Module with the installation guides.

NOTE: Ensure that Management Module is firmly seated against backplane.

4. Rotate the attached panel fastener screw clockwise to secure the Management

Module to the PointSystem™ chassis.

PWR

CPSMC-0800
8-Slot Chassis

Mpls, MN 55344

Mpls, MN 55344

Input Power:

Input Power:
110-240 VAC

110-240 VAC
1.6A max. (60W max)

1.6A max. (60W max)
50/60 Hz

50/60 Hz

10BASE-T

INPORT

MCCM10

MGMT

MASTER

OUTPORT

12C

12C-1

TERM

INIT

RX

TX

LNK

PWR

RESET

DB-9

Panel Fastener Screw

Advertising