Cable Specifications

Null Modem Cable

The Null Modem Cable is used for connecting a terminal or terminal emulator to
the Management Module’s DB-9 connecdtor to access the command-line interface.

The table below shows the pin assignments for the DB9 cable.

Function

Mnemonic

Pin

Carrier Detect

CD

1

Receive Data

RXD

2

Transmit Data

TXD

3

Data Terminal Ready

DTR

4

Signal Ground

GND

5

Data Set Ready

DSR

6

Request To Send

RTS

7

Clear To Send

CTS

8

RJ-45 Cable

Category 5:
Gauge:

24 to 22 AWG

Attenuation:

22.0 dB /100m @ 100 MHz

Maximum Cable Distance:

100 meters

• Straight-Through OR Crossover cable may be used.
• Shielded Twisted-Pair(STP) OR Unshielded Twisted-Pair(UTP) may be used.
• All pin pairs (1&2, 3&6, 4&5, 7&8) are active in a Gigabit Ethernet™ network.
• Use only dedicated wire pairs for the active pins:

(e.g., blue/white & white/blue, orange/white & white/orange, etc.)

• Do not use flat or silver satin wire.