To cascade two or more CPSMC0800-100 8-Slot chassis:

1. Locate one (1) Transition Networks CPSMC0800-100 Management Module cas-

cade cable (with RJ-45 connectors installed at both ends) for each set of two (2)
chassis to be cascaded.

NOTE: Transition Networks Management Module cascade cables are one (1)
meter long. Ensure that the chassis are installed within one (1) meter of each
other.

2. At the first chassis in the series: Plug the RJ-45 connector at one end of the cas-

cade cable into the Management Module’s RJ-45 port labeled “OUTPUT”.

3. At the next chassis in the series: Plug the RJ-45 connector at the other end of

the cascade cable into the Management Module’s RJ-45 port labeled “INPUT”.

4. At the same chassis as in step 3: Plug the RJ-45 connector at one end of the

cascade cable into the Management Module’s RJ-45 port labeled “OUTPUT”.

5. At the next chassis in the series: Plug the RJ-45 connector at the other end of

the cascade cable into the Management Module’s RJ-45 port labeled “INPUT”.

6. Repeat steps 4 and 5 until all chassis have been connected.

4.3

Connecting the Slide-in-Modules to the Network

Once the CPSMC0800-100 chassis has been installed, the Media Converter Slide-
in-Modules may be connected to the network.

CAUTION: Connect input/output network cables ONLY to Media Converter Slide-
In-Module connectors within the same network protocol (such as Ethernet-to-
Ethernet, Fast Ethernet-to-Fast Ethernet, ATM-to-ATM). Failure to observe this cau-
tion will cause data transfer to fail.

Refer to User’s Guides included with the Media Converter Slide-In-Modules for
cabling specifications and instructions.

Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600

10BASE-T

INPORT

MCCM10

MGMT

MASTER

OUTPORT

12C

12C-1

TERM

INIT

RX

TX

LNK

PWR

RESET

DB-9

CFETF1

10

SPD

PWR

FRX

CRX

FLNK

CLNK

10/100TX

RX

TX

10/100SX

LKS

PWR

LKM

Multimode

Singlemode

TX

RX

TX

RX

CFETF1

10

SPD

PWR

FRX

CRX

FLNK

CLNK

10/100TX

RX

TX

10/100SX

LKS

PWR

LKM

Multimode

Singlemode

TX

RX

TX

RX

CPSMC-0800
8-Slot Chassis

Mpls, MN 55344

Mpls, MN 55344

Input Power:

Input Power:
110-240 VAC

110-240 VAC
1.6A max. (60W max)

1.6A max. (60W max)
50/60 Hz

50/60 Hz

Check the individual User's Guides for specific information on

how to connect each Slide-in-Module to the network.

Advertising