For units equipped with ‘HI/LO’ valves the flame
adjustment is accomplished by rotating the ‘HI/LO’
adjustments knob located near the center of the gas
control valve. (Fig. 46)

It is important to periodically perform a visual check of
the pilot and burner flames. Compare them to Figure
47.
If the flame patterns appear abnormal contact a
qualified service provider for service and adjustment.

Flame Characteristics

Flame & Temperature Adjustment

LO

HI

FP390

FLAME ADJUSTMENT KNOB

11/21/96

Turn

counterclockwise

to increase

flame height

Turn clockwise

to decrease

flame height

Fig. 46 Flame adjustment knob for SIT valve.

FP1229

Pilot flames

11/02

FP1229

Fig. 47 Correct pilot flame appearance.

TL121

DV1000/DV1200

final position logs

12/11/03 djt

TL121

Fig. 44 Logs in final position (36RDV shown).

7. Ember tray ends beyond burner port area and area

in front of grate may be covered with lava rock to
suit individual appearance preferences.

8. Purge lines and test pilot operation.
9. Replace glass door. The door must be installed

before operating the fireplace.

10. Flame should not impinge (touch) on logs.
WARNING: Do not place lava rock or any other materi-
als on the burner. Use only certified material supplied
with this fireplace. Using uncertified materials will void
the warranty.

TL122

Dv logs

side view

12/11/03 djt

Back Log

Slot

Bracket

Bracket

Twig

Front Log

TL122

Fig. 45 Side view of logset.