Troubleshooting, Rdvn series direct vent gas fireplace, System checks – Temco Tool 36RDVN User Manual

Page 27

Advertising
background image

27

RDVN Series Direct Vent Gas Fireplace

20007628

Troubleshooting

SIT Millivolt Valve

NOTE: Before troubleshooting the gas control system, be sure external shut off is in the “ON” position.

WARNING: Before doing any gas control service work, remove glass front!

Table 1

Valve Type

Main Operator

Safety Magnet

NOVA MV Plus

Minimum Voltage

145mV

Hold-in Current

Less than 285mA

Coil Resistance

2.25Ω ± 0.5Ω

Drop-out Current

Greater than 125mA

Coil Resistance

0.108Ω ± 0.003Ω

Problem

Possible Cause

Solution

Pilot will not light.

Air in gas lines.

Bleed all air from gas lines.

Wrong inlet pressure.

With the main burner functioning, adjust the inlet pressure

regulator to supply gas to the appliance within the design

parameters of the appliance manufacturer. (Typically 7”NG,

11”LPG).

Defective spark electrode.

Replace piezo wire if insulation is cracked or the tip is cor-

roded.

Verify that the spark gap between the pilot and the electrode

is correct.

Defective piezo wire.

Replace piezo wire if insulation is damaged, or the wire is bro-

ken or corroded.

Safety interlock function engaged. Allow thermocouple to cool until the mv drops below the hold-

in requirements of the safety magnet, (30 seconds or less).

Re-light pilot.

Pilot will not hold.

Wrong inlet pressure.

With the main burner functioning, adjust the inlet pressure

regulator to supply gas to the appliance within design

parameters of the appliance manufacturer. (Typically 7”NG,

11”LPG)

Pilot adjustment screw not

After the pilot has been lit for approximately three minutes,

properly adjusted.

and only the thermo-generator wire connected to the main

operator head, measure the voltage across TPTH and TP.

This open circuit voltage should be between 500mv and

750mv. Tune the pilot adjustment screw until the mv reading

falls within these parameters. (Counter-clockwise increases

mv reading, clockwise decreases).

Thermocouple or

Make certain that the thermocouple and thermo-generator are

thermo-generator not properly

fully inserted and tightened into their receptacles in the pilot

inserted into the pilot housing.

head. The thermocouple should be threaded into the valve

hand-tight, plus 1/4 turn with a wrench.

Thermocouple or

With the thermocouple and thermo-generator tips cool, clean

thermo-generator has film

the upper 3/8” with a very fine emery cloth.

build-up on tip.

Electrical resistance too high.

Using a very fine emery cloth, clean thermo-generator and

thermocouple connections at valve. Tighten thermocouple into

valve hand-tight, plus 1/4 turn with a wrench.

Defective thermocouple.

Verify that thermocouple is not kinked or damaged. Check

(mv Plus systems)

open circuit voltage of thermocouple. Voltage should be

between 18mv and 28mv. If voltage is less than 14mv,

replace thermocouple.

System Checks