Temco Tool 36RDVN User Manual

Page 31

Advertising
background image

31

RDVN Series Direct Vent Gas Fireplace

20007628

NOTE: Failure to adjust air shutter to the proper set-

ting will produce sooting.

4. Fasten pilot to burner bracket with two (2) screws.

5. Replace grate assembly.

WARNING: Failure to position the parts in accor-
dance with these diagrams or failure to use only
parts specifically approved with this heater may
result in property damage or personal injury.

Replace Pilot Orifice

1. The pilot hood is held in place by spring pressure.

Remove the hood by pulling it directly up from the
pilot bracket. (Fig. 53)

2. Insert a 3/32” (4 mm) Allen wrench into the hex-

agonal keyway of the injector (Fig. 53) and rotate it
counterclockwise until it is free of the injector journal.
(Fig. 53)

3. Verify that the new injector is proper for the applica-

tion. The injector size is stamped on the side of the
injector near the top. LPG injectors have a groove
machined around their circumference near the top,
while the NG injectors do not have a groove. (Fig.

T207

remove pilot hood

1/8/04 djt

Pilot

Hood

Conversion

Orifice

Allen

Wrench

T207

Fig. 53 Remove pilot hood and orifice. Insert conversion
orifice.

T208

conversion

injectors

1/8/04 djt

T208

LPG

NG

Fig. 54 Injectors.

2. Move burner tube back to original position, tighten

split nut assembly and bend tabs back up.

3. Set the air shutter opening for propane/LP gas.

Tighten air shutter screw. (Refer to Figure 52 and
Chart on Page 35)

T207

air shutter

setting

1/8/04 djt

T207

Fig. 52 Air shutter settings for propane/LP gas.

3/8” - 33RDVP
3/8” - 36RDVP
3/8” - 39RDVP

Fig. 51 Replace burner orifice with correct conversion orifice.

T259

remove burner

orifice

6/04

Split Nut Assembly

Air Shutter

Burner Orifice

T259

All Models:
1. Using a suitable tool replace natural orifice #47 with

propane orifice #56 for model 33RDVP, or replace
natural orifice #45 with propane orifice #55 for model
36RDVP, or replace natural orifice #42 with propane
orifice #54 for model 39RDVP furnished with conver-
sion kit. Tighten orifice with suitable tool until gas
tight. (Fig. 51)

54) Install the conversion orifice furnished with unit
(Conversion Kit).

4. Insert the Allen wrench into the end of the injector.

Insert the injector into injector journal, and rotate
the injector clockwise until a torque of 9 in/lbs. is
achieved. Replace the pilot hood by aligning the
tab on the base of the hood with the slot in the side
of the pilot journal. Push the hood down directly
onto the pilot bracket. (Fig. 53) The hood must sit
squarely on the bracket for proper operation. Check
to insure the hood is properly seated onto the pilot
bracket.

Advertising
This manual is related to the following products: