Maintenance – Temco Tool 36RDVN User Manual

Page 34

Advertising
background image

34

RDVN Series Direct Vent Gas Fireplace

20007628

Motor and Blower for Fan Kit (optional)
This motor has been factory oiled and under normal
operating conditions should not require oiling.

WARNING: Ensure the power is turned off to
the fireplace before servicing.

Cleaning
This unit should be cleaned and serviced by a Qualified
Gas Technician at least annually. More frequent clean-
ing may be necessary if pet hair accumulates, dust and
lint are present, or if the unit is located in a high traffic
area. A Qualified Agency is defined in the Gas Code.
Cleaning should include burner tubes, orifice/injectors
(refer to section B.3 National Fuel Gas Code), logs,
ceramic base, and pilot assembly. It is recommended
that the sediment trap in the gas line be emptied and
cleaned at this time. (Refer to Section 3.7.2 National
Fuel Gas Code)
Burner, Pilot, Firebox and Logs

CAUTION: Before cleaning or moving logs
or other parts of the unit, be sure to read the
section on important safeguards.

Cleaning should be done before the logs are used each
year and after long periods of non-use. All cleaning
should be carried out when the appliance is cold.
Cleaning will be required under normal use. Dusting the
front grate or the control knob panel may be required
occasionally. Do not use any cleaning fluids to clean
the logs or any other part of the appliance.
If the flames show any unusual shapes or behavior, or if
the burners fail to ignite properly, then the burner holes
may require cleaning. If this occurs, contact your near-
est dealer to get the appliance serviced.
Alternatively, the appliance can be cleaned by removing
all the logs. Handle the logs gently so as not to damage
them. Always lift each log by holding it carefully at each
end.

Maintenance

After the logs are removed allowing access to the burn-
er area, use a vacuum cleaner to carefully remove dust
and loose particles from the base, logs and from around
the burners. Gloves are recommended to prevent the
ceramic fibers that compose the logs from pricking your
skin. If the skin is pricked, wash gently with soap and
water. Use extreme caution in cleaning around the pilot.
The pilot should not be moved or altered from the origi-
nal factory setting (Pilot to burner preset location). The
burner should be placed back into its original locked
and secure position after cleaning and servicing(proper
location of burners are critical). NOTE: All replacements
and repairs should be performed by a qualified techni-
cian (contact your nearest dealer). After cleaning and/or
repairs, follow instructions for positioning of logs as
illustrated on Page 24.
Glass
It will be necessary to clean the glass periodically. Dur-
ing startup it is normal for condensation to form on the
glass and cause dirt, lint, etc., to adhere to the inner
surface of the glass. There also will be a film deposited
on the glass during the initial use of the fireplace due
to initial curing of the paint. It is recommended that the
glass be cleaned with a non-abrasive household clean-
er and warm water. Be sure to rinse and dry the glass
well as not to leave any marks. It may be necessary to
clean the glass two to three times a season depending
on use of the fireplace.

Advertising
This manual is related to the following products: