Rdvn series direct vent gas fireplace, Convert valve to lp – Temco Tool 36RDVN User Manual

Page 32

Advertising
background image

32

RDVN Series Direct Vent Gas Fireplace

20007628

Kit Number

Conversion Parts Included with Kit

33DVCKP

36DVCKP

39DVCKP

Main Burner Orifice - LP

76776

20007908

20007907

Label, Conversion

10002876

10002876

10002876

Pilot, Orifice - LP

76263

76263

76263

Conversion Pressure Regulator Assembly - LP

74655

74655

74655

Label, SIT Valve

--

--

--

Convert Valve to LP

1. Using a Torx T20 bit or slotted screwdriver, remove

and discard the three (3) pressure regulator mount-
ing screws (A), pressure regulator tower (B) and
diaphragm (C). (Fig. 55)

2. Insure the rubber gasket (D) is properly positioned

and install the new HI/LO pressure regulator assem-
bly to the valve using the new screws (E) supplied
with the kit. Tighten screws securely. (Fig. 56)

FC107

SIT820

valve conversion

10/03

A

B

C

OFF

PILO

T

ON

FC107

Fig. 55 Remove mounting screws, pressure regulator tower
and diaphragm assembly, and discard.

D

E

F

FC108

SIT

regulator

conversion

10/03

OFF

PILOT

ON

FC108

Fig. 56 Replace regulator.

Gas Supply Pressure (inches w.c.)

Minimum

Normal Maximum

LP (Propane)

10.8

11.0

14.0

Manifold Pressure (inches w.c.)

Nornal (HI)

Normal (Low)

LP (Propane)

10.0”

6.3”

Pressure ranges are:

3. Install the enclosed installation label (F) to the valve

body where it can be seen.

4. Apply gas to system and relight appliance according

to manufacturer’s instructions.

5. With the main burner “ON”, test the new pressure

regulator assembly for leaks using a soap solution.

6. Relight the main burner in both the HI and LO posi-

tions, and verify proper burner ignition and opera-
tion.

7. Check inlet and manifold pressures. Loosen screw

in test port 1/2 turn to measure pressure. Tighten
screw when measurement is complete.

Manifold pressure can be measured by using a 5/16”
I.D. hose in the right hand side of the valve and con-
necting a manometer. Two test gauge ports are acces-
sible for test gauge connection. Refer to Page 32.