Temco Tool 36RDVN User Manual

Page 35

Advertising
background image

35

RDVN Series Direct Vent Gas Fireplace

20007628

Normal and High

Direct Vent Units - Inputs - Orifice Size - Altitude

BTU/Hr

BTU/Hr

Manifold Pressure Orifice 0 - 2000ft. Altitude in USA

Model

Min. Input

Max. Input

@ Max.

Orifice 0-4500ft Altitude in Canada

33RDVN

13,000

18,000

3.5”w.c.

#47 DMS

33RDVP

13,000

18,000

10.0” w.c.

#56 DMS

36RDVN

13,000

20,000

3.5” w.c.

#45 DMS

36RDVP

13,000

20,000

10.0” w.c.

#55 DMS

39RDVN

15,000

22,000

3.5” w.c.

#43 DMS

39RDVP

15,000

22,000

10.0” w.c.

#54 DMS

Conversion Kits

Change Natural Change Propane

Model

to Propane

to Natural

33RDVN

33DVCKP

--

33RDVP

--

36RDVN

36DVCKP

--

36RDVP

--

39RDVN

39DVCKP

--

39RDVP

--

IMPORTANT: Always check for gas leaks with a
soap and water solution. Do not use open flame for
leak testing.

Air Shutter Settings

Opening

Model

“A”

33RDVN

1/32” (1.0 mm)

33RDVP

3/8” (9.5mm)

36RDVN

1/32” (1.0 mm)

36RDVP

3/8” (9.5mm)

39RDVN

1/32” (1.0 mm)

39RDVP

3/8” (9.5mm)

NOTE: These are minimum settings. Air shutter open-
ings may be increased to prevent flame sooting.

T203

Air shutter

12/12/03 djt

T203

Opening
“A”

Fig. 57 Air shutter opening.