Rdvn series direct vent gas fireplace, Eb-1 electrical box, Alternate switch location – Temco Tool 36RDVN User Manual

Page 9

Advertising
background image

9

RDVN Series Direct Vent Gas Fireplace

20007628

The EB-1 Electrical junction box has been fitted stand-
ard on this model to allow for the easy connection of an
optional fan kit.
To connect the EB-1 box to the house electrical supply
follow the steps below.
1. Unscrew retaining screw from EB-1 base plate (Fig.

8) and remove the EB-1 assembly from the appli-
ance.

2. Remove the front cover of the EB box.
3. Remove the plug socket assembly from the EB-1

box.

4. Feed the supply line in through the EB-1 opening in

the side of the appliance and then through the back
of the EB-1 assembly. (Fig. 8)

5. Connect the black wire of the power supply line to

the brass screw (polarized) of the socket assembly.

6. Connect the white wire of the power line to the

chrome screw of the socket assembly.

7. Connect the ground wire of the supply line to the

green screw of the socket assembly.

8. Refit the socket assembly back into the electrical

box and replace the cover plate. Secure the cable
with the clamp on the outside of the EB-1 base
plate and refit the EB-1 assembly to the unit with the
screw removed in step 1.

EB-1 Electrical Box

It is strongly suggested that the wiring of
the EB-1 Electrical Junction Box be carried
out by a licensed electrician.

Ensure that the power to the supply line
has been disconnected before commenc-
ing this procedure.

FP580
INSTA VENT FREE
EB1 JUNCTION BOX
11/18/97

OUTSIDE

FRONT OF UNIT

INSIDE

FRONT OF

UNIT

Electrical Box

Retaining Screw

FP580

Fig. 8 EB-1 receptacle.

Do not wire the remote ON/OFF wall
switch for the gas fireplace to the 120 volt
power supply.

Alternate Switch Location

The remote switch can be installed on the front/side of
the access door. Simply mount the switch to the bracket
provided and screw the bracket to either side of the
frame, lining up the screws with the pre-punched holes.
(Fig. 7)

TP

TH

TP

TH

FP1224

Remote switch

11/02

Remote ON/OFF

Switch or Thermostat or

Remote Control

Gas
Control
Valve

FP1224

Fig. 6 Remote switch wiring diagram.

T256

alternate

remote switch

location

5/10/04 djt

T256

Fig. 7 Alternate switch location.

The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the ab-
sence of local codes, with the current CSA
C22.1 Canadian Electrical Code.

For USA installations follow local codes
and the national electrical code ANSI/
NFPA No. 70.

Advertising
This manual is related to the following products: