Rdvn series direct vent gas fireplace, Fuel conversion instructions, Replace burner orifice – Temco Tool 36RDVN User Manual

Page 30

Advertising
background image

30

RDVN Series Direct Vent Gas Fireplace

20007628

Fuel Conversion Instructions

WARNING: This HI/LO conversion kit must ONLY be
applied as part of a conversion kit supplied by the
appliance manufacturer for the specific appliance
and type of gas being converted.
The conversion shall be carried out in accordance
with the requirements of the provincial authori-
ties having jurisdiction and in accordance with the
requirements of the CSA B149.2 Installation Code
(Canada) and with the requirements of the National
Fuel Gas Code Z223.1/NFPA 54 (United States).
WARNING: This conversion kit shall be installed
by a qualified service agency in accordance with
the manufacturer’s instructions and all applicable
codes and requirements of the authority having
jurisdiction. If the information in this instruction is
not followed exactly, a fire, explosion or production
of carbon monoxide may result causing property
damage, personal injury or loss of life. The qualified
service agency is responsible for the proper instal-
lation of this kit. The installation is not proper and
complete until the operation of the converted appli-
ance is checked as specified in the manufacturer’s
instructions supplied with the kit.
Installer Notice: Using an ink pen, fill out the re-
quired information on the conversion label. Remove
the backing from label and stick label in a visible
position on bottom of fireplace close to gas valve.
Installer Notice: These instructions must be left
with the appliance.
Instructions for converting your fireplace from Natural
gas to Propane/LP gas.
All fireplaces are shipped from the factory equipped to
operate on Natural gas. To convert the fireplace to op-
erate on Propane/LP gas, follow the instructions below.
Please see the appropriate parts list for your model for
parts included with the fireplace.
Check the items in the kit with the parts list. Notify the
supplier of any items that are missing before installing
the conversion kit.
1. Turn off gas supply.
2. Turn off the electrical supply to the appliance if so

equipped.

Replace Burner Orifice

All Models:
Remove the two (2) screws holding the pilot to the
burner bracket.

33RDVN:
1. Bend retaining bracket away from burner tube. (Fig.

48)

2. With suitable tool, loosen the split nut assembly

from the air shutter. (Fig. 49) Lift burner tube up and
away.

Fig. 50 Bend tabs down, loosen split nut assembly and slide
burner tube to the left.

T257

fuel conversion

6/04

Burner Tabs

Split Nut Assembly

T257

Attention: All fireplaces are shipped from the fac-
tory equipped for natural gas. Units must be con-
verted for use with propane (LP) gas.

FC100

fuel conversoin

burner tube

7/21/99 djt

Retaining Bracket

Burner Tube

FC100

Fig. 48 Bend retaining bracket away from tube.

FC105

manifold to

air shutter

4/30/02 djt

Burner Tube

Air Shutter

Split Nut Assembly

FC105

Fig. 49 Loosen split nut assembly from air shutter and re-
move burner tube.

36/39RDVN:
1. Remove lava rock to expose screws and remove

grate assembly.

2. Use screwdriver and bend burner tabs outward. (Fig.

50)

3. Loosen the split nut assembly to remove from

burner/air shutter. Slide burner tube to the left and
off burner orifice. (Fig. 50)