250

8.JOB STATUS

8

6. Error Code

If an error occurs while using the optional Fax, optional Internet Fax or optional scan, the error code is dis-
played in the status of each log. Take an appropriate action with reference to the following.

Fax / Internet Fax

Error code

Problem

What to do

Fax
0012

Original jam

Clear the jammed original.

0013

Door open

Firmly close the open door.

0020

Power interruption

Check the power interruption report.

0030

Reset

Transmission is cancelled. (The transmission is terminated by
the jammed printing paper during the Direct Transmission.)

0033

Polling Error

Check polling options setup (Security Code, etc.), and check if
the polling document exists.

0042

Memory full

Make sure that there is sufficient memory before making the call
again.

0050

Line busy

Retry communications.

0053

Security Mismatch in
Relay or Mail Box
transmission

Confirm the remote party’s Security Code, system password,
and your setup.

00B0 - 00B5
00C0 - 00C4
00D0 - 00D2
00F0, 00F1

Signal Error or Line
Condition Error

Retry communications. Frequent failures may indicate a phone
line problem. If possible, move the unit to another line and try
your communications again.

00E8

HDD Error

Retry communications.

Internet Fax
1C10

System access abnor-
mality

Turn the power OFF and then back ON.
Perform the job in error again. If the error still occurs, contact
your service representative.

1C11

Insufficient memory

When there are running jobs, perform the job in error again after
the completion of the running jobs. If the error still occurs, turn
the power OFF and then back ON, and perform the job again.

1C12

Message reception
error

Turn the power OFF and then back ON.
Perform the job in error again.

1C13

Message transmission
error

Turn the power OFF and then back ON.
Perform the job in error again.

1C14

Invalid parameter

When a template is used, form the template again. If the error
still occurs, turn the power OFF and then back ON, and perform
the job again.

1C15

Exceeding file capacity Ask your administrator to change the “Fragment Page Size” set-

ting for the Internet Fax setting, or reduce the number of pages
and perform the job again.

1C20

System management
module access abnor-
mality

Turn the power OFF and then back ON.
Perform the job in error again. If the recovery is still not com-
pleted, contact your service representative.

1C21-1C22

Job control module
access abnormality

Turn the power OFF and then back ON.
Perform the job in error again. If the recovery is still not com-
pleted, contact your service representative.