Electrical data – Trane TSC060-120 User Manual

Page 34

Advertising
background image

34

RT-PRC016-EN

Table ED-3 — Electrical Characteristics - Evaporator Fan Motor - 50 Hz

Standard Evaporator Fan Motor

Oversized Evaporator Fan Motor

Unit

Amps

Amps

Model No.

No.

Volts

Phase

HP

FLA

LRA

No.

Volts

Phase

HP

FLA

LRA

TSC060AD

1

380-415

3

1.5

4.3

25.3

-

-

-

-

-

-

TSC072AD

1

380-415

3

1.5

4.3

25.3

1

380-415

3

2.0

5.3

36.4

TSC090AD

1

380-415

3

2.0

5.3

36.4

1

380-415

3

3.0

7.0

57.0

TSC102AD

1

380-415

3

2.0

5.3

36.4

1

380-415

3

3.0

7.0

57.0

TSC120AD

1

380-415

3

3.0

7.0

57.0

-

-

-

-

-

-

Table ED-4 — Electrical Characteristics - Compressor Motor and Condenser Motor - 50 Hz

Compressor Motor

Condenser Fan Motor

Unit

Amps

Amps

Model No.

No.

Volts

Phase

HP

1

RPM

RLA

1

LRA

1

No.

Phase

HP

FLA

LRA

TSC060AD

1

380-415

3

5.7

2875

9.5

74.00

1

1

0.40

1.9

2.8

TSC072AD

1

380-415

3

7.5

2875

12.7

95.00

1

1

0.75

2.8

7.1

TSC090AD

1

380-415

3

8.3

2875

13.20

100.00

1

1

0.75

2.8

7.1

TSC102AD

2

380-415

3

6.0/3.8

2875

9.3/6.9

74.0/48.0

1

1

0.75

2.8

7.1

TSC120AD

2

380-415

3

6.0/4.8

2875

9.9/8.5

74.0/61.8

1

1

0.75

2.8

7.1

Note:
1. Comp1/Comp2

Electrical
Data

Table ED-1 — Unit Wiring

Standard Indoor Fan Motor

Oversized Indoor Fan Motor

Unit

Minimum

Maximum Fuse

Minimum

Maximum Fuse

Unit

Operating

Circuit

Size Or Maximum

Circuit

Size Or Maximum

Model No.

Voltage Range

Ampacitiy

Circuit Breaker

1

Ampacitiy

Circuit Breaker

1

TSC060AD

342-456

17.7

25

17.7

25

TSC072AD

342-456

23.2

35

24.2

35

TSC090AD

342-456

24.8

35

26.5

35

TSC102AD

342-456

26.8

35

28.5

35

TSC120AD

342-456

31.2

40

31.2

40

Notes:
1. All units to be installed under local codes

Table ED-2 — Unit Wiring With Electric Heat Single Point Connection — 380-415 Volts

Standard Indoor Fan Motor

Oversized Indoor Fan Motor

Minimum

Maximum Fuse

Minimum

Maximum Fuse

Unit

Heater

Heater

2

Control

Circuit

Size Or Maximum

Circuit

Size Or Maximum

Model No.

Model No.

kW Rating

MBH

Stages

Ampacitiy

Circuit Breaker

1

Ampacitiy

Circuit Breaker

1

TSC060AD

BAYHTRR412A

7.5 / 9.0

26 / 31

2

19.8 / 21.0

25 / 25

19.8 / 21.0

25 / 25

BAYHTRR418A

10.9 / 13.0

38 / 45

2

26.1 / 28.0

30 / 30

26.1 / 28.0

30 / 30

BAYHTRR423A

14.4 / 17.2

50 / 59

2

32.8 / 35.3

35 / 40

32.8 / 35.3

35 / 40

TSC072AD

BAYHTRS418A

11.3 / 13.5

39 / 47

1

26.9 / 28.9

35 / 35

28.1 / 30.1

35 / 35

BAYHTRS427A

16.9 / 20.2

58 / 69

2

37.5 / 40.5

40 / 45

38.8 / 41.8

40 / 45

BAYHTRS436A

22.6 / 26.9

78 / 92

2

48.3 / 52.1

50 / 60

49.5 / 53.4

50 / 60

TSC090AD

BAYHTRS418A

11.3 / 13.5

39 / 47

1

28.1 / 30.1

35 / 35

30.3 / 32.3

35 / 35

BAYHTRS427A

16.9 / 20.2

58 / 69

2

38.8 / 41.8

40 / 45

40.9 / 43.9

45 / 45

BAYHTRS436A

22.6 / 26.9

78 / 92

2

49.5 / 53.4

50 / 60

51.6 / 55.5

60 / 60

TSC102AD

BAYHTRT427A

16.9 / 20.2

58 / 69

2

38.8 / 41.8

40 / 45

40.9 / 43.9

45 / 45

BAYHTRT436A

22.6 / 26.9

78 / 92

2

49.5 / 53.4

50 / 60

51.6 / 55.5

60 / 60

TSC120AD

BAYHTRT427A

16.9 / 20.2

58 / 69

2

40.9 / 43.9

45 / 45

40.9 / 43.9

45 / 45

BAYHTRT436A

22.6 / 26.9

78 / 92

2

51.6 / 55.5

60 / 60

51.6 / 55.5

60 / 60

BAYHTRT454A

33.8 / 40.4

116 / 138

2

73.1 / 79.0

80 / 80

73.1 / 79.0

80 / 80

Notes:
1. All units to be installed under local codes
2. kW and MBH shown for 380V / 415V

Advertising