Texas Instruments TMS320C645X User Manual

Page 67

Advertising
background image

www.ti.com

SRIO Functional Description

Table 24. Enable and Enable Status Bit Field Descriptions (continued)

Name

Bit

Access

Description

BLK1_EN

0

R/W

Controls reset to logical block 1, which is the LSU.

0 = Logical block 1 disabled (held in reset, clocks disabled)

1 = Logical block 1 enabled

BLK1_EN_STAT

0

R

Indicates state of BLK1_EN reset signal.

0 = Logical block 1 in reset and clock is off

1 = Logical block 1 enabled and clocking

BLK2_EN

0

R/W

Controls reset logical block 2, which is the MAU.

0 = Logical block 2 disabled (held in reset, clocks disabled)

1 = Logical block 2 enabled

BLK2_EN_STAT

0

R

Indicates state of BLK2_EN reset signal.

0 = Logical block 2 reset and clock is off

1 = Logical block 2 enabled and clocking

BLK3_EN

0

R/W

Controls reset logical block 3, which is the TXU.

0 = Logical block 3 disabled (held in reset, clocks disabled)

1 = Logical block 3 enabled

BLK3_EN_STAT

0

R

Indicates state of BLK3_EN reset signal.

0 = Logical block 3 reset and clock is off

1 = Logical block 3 enabled and clocking

BLK4_EN

0

R/W

Controls reset logical block 4, which is the RXU.

0 = Logical block 4 disabled (held in reset, clocks disabled)

1 = Logical block 4 enabled

BLK4_EN_STAT

0

R

Indicates state of BLK4_EN reset signal.

0 = Logical block 4 reset and clock is off

1 = Logical block 4 enabled and clocking

BLK5_EN

0

R/W

Controls reset logical block 5, which is port 0.

0 = Logical block 5 disabled (held in reset, clocks disabled)

1 = Logical block 5 enabled

BLK5_EN_STAT

0

R

Indicates state of BLK5_EN reset signal.

0 = Logical block 5 reset and clock is off

1 = Logical block 5 enabled and clocking

BLK6_EN

0

R/W

Controls reset to logical block 6, which is port 1.

0 = Logical block 6 disabled (held in reset, clocks disabled)

1 = Logical block 6 enabled

BLK6_EN_STAT

0

R

Indicates state of BLK6_EN reset signal.

0 = Logical block 6 in reset and clock is off

1 = Logical block 6 enabled and clocking

BLK7_EN

0

R/W

Controls reset to logical block 7, which is port 2.

0 = Logical block 7 disabled (held in reset, clocks disabled)

1 = Logical block 7 enabled

BLK7_EN_STAT

0

R

Indicates state of BLK7_EN reset signal.

0 = Logical block 7 in reset and clock is off

1 = Logical block 7 enabled and clocking

BLK8_EN

0

R/W

Controls reset to logical block 8, which is port 3.

0 = Logical block 8 disabled (held in reset, clocks disabled)

1 = Logical block 8 enabled

SPRU976 – March 2006

Serial RapidIO (SRIO)

67

Submit Documentation Feedback

Advertising