3 delete groups from a scan list – Tyco Electronics P5200 User Manual

Page 75

Advertising
background image

MM23772, Rev. F

75

2. Press

. The current priority status of the group will be displayed in column 10 of line three for a

time-out period. If the group is not part of the scan list the status will be blank.

3. While the status is displayed, press

to add the group to the scan list. is displayed on line three.

4. Press

a second time to set the group to Priority 2. A is displayed on line three.

5. Press

a third time to set the group to Priority 1. A is displayed on line three. The priority level

selection sequence only advances the group to next higher priority level and stops at priority level 1.
To select a lower priority level, the group must be deleted from the scan list and then added back to
the scan list. Each new group added to the scan list starts at the lowest priority. If the Priority 1 and
Priority 2 groups are already set and a new group is assigned as Priority 1 or Priority 2, the previously
assigned group will change to non-priority scanning. One of the following messages may be
momentarily displayed:

SCAN DIS The radio is not programmed to scan.

FIXED P1 A Priority 1 group has been pre-programmed into the radio. A new Priority 1 group

cannot be selected.

FIXD LST A fixed scan list has been pre-programmed into the radio. It is not possible to change

the list without reprogramming the radio.

To quickly view multiple group scan status, press either

or the



key. Then slowly

but consistently rotate the group knob. Each group status will appear on the display.

9.20.3

Delete Groups from a Scan List

Scan Model Radio:

1. With scan operation turned OFF, select the desired group to delete from the selected trunked system

group scan list.

2. Press



. The current status of the group is displayed for a time-out period.

3. While the current status is displayed, press



until the group from the scan list is "blank". The

sequence is "blank", , , ,"blank". Any group that is not in a trunked system group scan list will
show a "blank" for the time-out period when it is the selected channel.

System Model Radio:

1. With scan operation turned OFF, select the desired group to delete from the selected trunked system's

group scan list.

2. Press



. The current status of the group is displayed for a time-out period.

3. While the status is displayed, press



to delete the group from the scan list. , ,or turns OFF.

Any group that is not in a trunked system group scan list will show a "blank" for the time out period
when it is the selected channel.

Advertising