Transition Networks SISTM10XX-162-LR User Manual

Page 10

Advertising
background image

5

OFF

Disable port Alarm

5

ON

Enable port Alarm. If the port’s link fails, the fault

LED will light up

OFF

Disable port Alarm

6

ON

Enable port Alarm. If the port’s link fails, the fault

LED will light up

OFF

Disable port Alarm

7

ON

Enable port Alarm. If the port’s link fails, the fault

LED will light up

OFF

Disable port Alarm

8

ON

Enable port Alarm. If the port’s link fails, the fault

LED will light up

OFF

Disable the ring master function

9

ON

Enable the switch as the ring master

in the X-Ring

group

[NOTE]

1.

When port alarm function is enabled, the fault LED will on and Alarm relay will activity when

port failure occurs.

2.

Please restart the switch after the X-Ring DIP switch is set.

LED Indicators

There are 7 diagnostic LEDs located on the front panel of the industrial switch. They provide real-

time information of system and optional status. The following table provides description of the LED

status and their meanings for the switch.

LED

Status

Meaning

Green

The switch unit is power on

Power

Off

The switch unit is no power input

Green

Power on

Power 1

Off

No power inputs

Power 2

Green

Power on

Advertising